ResearchTrend.AI
  • Papers
  • Communities
  • Events
  • Blog
  • Pricing
Papers
Communities
Social Events
Terms and Conditions
Pricing
Parameter LabParameter LabTwitterGitHubLinkedInBlueskyYoutube

© 2025 ResearchTrend.AI, All rights reserved.

  1. Home
  2. Papers
  3. 2505.03498
34
0

MRI motion correction via efficient residual-guided denoising diffusion probabilistic models

6 May 2025
Mojtaba Safari
Shansong Wang
Qiang Li
Zach Eidex
Richard L. J. Qiu
Chih-Wei Chang
H. Mao
Xiaofeng Yang
    DiffM
    MedIm
ArXivPDFHTML
Abstract

Purpose: Motion artifacts in magnetic resonance imaging (MRI) significantly degrade image quality and impair quantitative analysis. Conventional mitigation strategies, such as repeated acquisitions or motion tracking, are costly and workflow-intensive. This study introduces Res-MoCoDiff, an efficient denoising diffusion probabilistic model tailored for MRI motion artifact correction. Methods: Res-MoCoDiff incorporates a novel residual error shifting mechanism in the forward diffusion process, aligning the noise distribution with motion-corrupted data and enabling an efficient four-step reverse diffusion. A U-net backbone enhanced with Swin-Transformer blocks conventional attention layers, improving adaptability across resolutions. Training employs a combined l1+l2 loss, which promotes image sharpness and reduces pixel-level errors. Res-MoCoDiff was evaluated on synthetic dataset generated using a realistic motion simulation framework and on an in-vivo dataset. Comparative analyses were conducted against established methods, including CycleGAN, Pix2pix, and MT-DDPM using quantitative metrics such as peak signal-to-noise ratio (PSNR), structural similarity index measure (SSIM), and normalized mean squared error (NMSE). Results: The proposed method demonstrated superior performance in removing motion artifacts across all motion severity levels. Res-MoCoDiff consistently achieved the highest SSIM and the lowest NMSE values, with a PSNR of up to 41.91+-2.94 dB for minor distortions. Notably, the average sampling time was reduced to 0.37 seconds per batch of two image slices, compared with 101.74 seconds for conventional approaches.

View on arXiv
@article{safari2025_2505.03498,
  title={ MRI motion correction via efficient residual-guided denoising diffusion probabilistic models },
  author={ Mojtaba Safari and Shansong Wang and Qiang Li and Zach Eidex and Richard L.J. Qiu and Chih-Wei Chang and Hui Mao and Xiaofeng Yang },
  journal={arXiv preprint arXiv:2505.03498},
  year={ 2025 }
}
Comments on this paper